Home Categories Send inquiry

YCX8 Series DC Combiner Box

Features

● Multiple solar photovoltaic arrays can be connected simultaneously, with a maximum of 6 circuits; ● Rated input current of each circuit is 15A (customizable as required); ● The output terminal is equipped with a photovoltaic DC high-voltage lightning protection module that can withstand a maximum lightning current of 40kA; ● High voltage circuit breaker is adopted, with DC rated working voltage up to DC1000, safe and reliable; ● The protection level reaches IP65, meeting the use requirements for outdoor installation.

Selection

YCX8 I 2/1 15/32 8
Model Functions Input circuit/  Output circuit Input current per series/  Maximum output current Shell type
Photovoltaic box I: Isolation switch box 1/1: 1 input 1 output 2/1: 2 input 1 output 2/2: 2 input 2 output 3/1: 3 input 1 output 3/3: 3 input 3 output 4/1: 4 input 1 output 4/2: 4 input 2 output 4/4: 4 input 4 output 5/1: 5 input 1 output 5/2: 5 input 2 output 6/2: 6 input 2 output 6/3: 6 input 3 output 6/6: 6 input 6 output 15A(Customizable)/ Match as needed Terminal box: 4, 6, 9, 12, 18, 24, 36 Plastic distribution box : T Fully plastic sealed box : R
IF: Isolation switch box with fuse
DIS: Door clutch combiner box
BS: Overload lightning protection box (miniature)
IFS: Photovoltaic combiner box
IS: Isolation lightning protection box
FS: Overload lightning protection box (fuse)
* Due to the large number of scheme combinations, the shell part (dashed box content) is only used for internal selection and not for product marking models. The product will be produced according to the company's standard scheme. (To be confirmed with the customer before production). * if the customer customizes other solutions, please contact us before placing an order.

Technical data

Model YCX8-I YCX8-IF YCX8-DIS YCX8-BS YCX8-IFS YCX8-IS YCX8-FS
Rated insulation voltage(Ui) 1500VDC
Input 1、2、3、4、6
Output 1、2、3、4、6
Maximum voltage 1000VDC
Maximum input current 1~100A
Maximum output current 32~100A
Shell frame
Waterproof terminal box: YCX8-return circuit -
Plastic distribution box: YCX8-T
Fully plastic sealed box: YCX8-R -
Configuration
Photovoltaic isolation switch - -
Photovoltaic fuse - - -
Photovoltaic MCB - - - - - -
Photovoltaic surge  protective device - -
Anti reflection diode
Monitoring module
Input/output port MC4
PG waterproof cable connector
Component parameters
Photovoltaic isolation switch Ui 1000V - -
1200V - -
Ie 32A - -
55A - -
Photovoltaic MCB Ie(max) 63A - - - - - -
125A - - - - - -
DC polarity Yes - - - - - -
No - - - - - -
Photovoltaic surge protective device Ucpv 600VDC - -
1000VDC - -
1500VDC - -
Imax 40kA - -
Photovoltaic fuse Ie(max) 32A - - -
63A - - -
125A - - -
Use environment
Working temperature -20℃~+60℃
Humidity 0.99
Altitude 2000m
Installation Wall mounting
■ Standard;  □ Optional; - Non

YCX8 Series DC Combiner Box Related Video: