Features
Makes photovoltaic power generation safer
Quick connection of photovoltaic cables and easy to install
Extremely low contact resistance Waterproof and dustproof design
Excellent resistance to high and low temperatures, fire, and UV radiation
Selection
PvT |
— |
P |
|
|
|
DC1500 |
Model |
Installationcategory |
Rated current |
Rated voltage |
Photovoltaic Special Connector |
/: Plug-inconnection
P: Panel installation connection
Hard connection:
LT2: 1-to-2
LT3: 1-to-3
LT4: 1-to-4
LT5: 1-to-5
LT6: 1-to-6
Soft connection:
LTY2: 1-to-2
LTY3: 1-to-3
LTY4: 1-to-4 |
|
DC1000
DC1500 |
D:Diode |
10A
15A
20A |
F:Fuse |
DC1000 |
Technical data
Connector system |
Φ4mm |
Rated voltage |
1000V DC (IEC) |
Rated current |
17A (1.5mm²) |
22A (2.5mm²; 14AWG) |
30A (4mm²; 6mm²; 12AWG, 10AWG) |
Test voltage |
6kV (50Hz, 1min) |
Ambient temperature range |
-40°C...+90°C (IEC) -40°C...+75°C (UL) |
Upper limiting temperature |
+105°C (IEC) |
Protection degree, mated |
IP67 |
Touch protection level, unmated |
IP2X |
Comtact resistance of plug connectors |
0.5mΩ |
Safety class |
II |
Contact material |
Messing, verzinnt Copper Alloy, tin plated |
Insulation material |
PC/PPO |
Locking system |
Snap-in |
Flame class |
UL-94-Vo |
Salt mist spray rest, degree of severity 5 |
IEC 60068-2-52 |
Overall and mounting dimensions( mm)
Technical data
Connector system |
Φ4mm |
Rated voltage |
1500V DC(IEC) 1000V/1500V DC(UL) |
Rated current |
17A(1.5mm²) |
22A(2.5mm²;14AWG) |
30A(4mm²;6mm²;10mm²;12AWG,10AWG |
Test voltage |
6kV(50HZ,1min.) |
Ambient temperature range |
-40°C...+90°C(IEC) -40C...+75C(UL) |
Upper limiting temper ature |
+105°C(IEC) |
Degree of protection,mated |
IP67 |
unmated |
IP2X |
Comtact resistanceof plug connectors |
0.5mΩ |
Safetyclass |
II |
Contact material |
Messing,verzinnt Copper Alloy,tin plated |
Insulation material |
PC/PV |
Locking system |
Snap-in |
Flame class |
UL-94-V0 |
Salt mist spray test,degree of severity 5 |
IEC 60068-2-52 |
Overall and mounting dimensions( mm)