Selection
YCF8 |
- |
63 |
PVS |
DC1500 |
Model |
Shell frame |
Product type |
Rated Voltage |
Fuse |
63 |
PVS:Photovoltaic DC sailboat |
DC1500V |
Technical data
Model |
YCF8-63PVS |
Fuse size(mm) |
10 ×85 |
14 ×85 |
Rated working voltage Ue(V) |
DC1500 |
Rated insulation voltage Ui(V) |
DC1500 |
Rated short-circuit breaking capacity (KA) |
20 |
Operating level |
gPV |
Standard |
IEC60269-6, UL4248-19 |
Number of poles |
1P |
Installation method |
TH-35 Din-rail installation |
Operating environment and installation |
Working temperature |
-40℃≤X≤+90℃ |
Altitude |
≤2000m |
Humidity |
When the maximum temperature is+40℃, the relative humidity of the air shall not exceed 50%, and higher humidity can be allowed at lower temperatures, For example +90% at 25℃ . Special measures shall betaken for occasional condensation due to temperature changes; |
Installation environment |
In a place where there is no explosive medium and the medium is not enough to corrode metal and damage insulation gas and conductive dust. |
Pollution degree |
Level 3 |
Installation category |
III |
Fuse adapter table
Fuse(Base) |
Fuse |
Model |
Model |
Current rating |
Voltage |
YCF8-63PVS DC1500 |
YCF8-1085 |
2, 3, 4, 5, 6, 8, 10, 15, 16, 20, 25, 30, 32 |
DC1500 |
YCF8-1485 |
30-50 |
Selection
YCF8 |
- |
1085 |
25A |
DC1500 |
Product name |
Size |
Rated current |
Rated Voltage |
Fuse link |
1085: 10×85(mm) |
2-32A |
DC1500V |
1485: 14×85(mm) |
40-50A |
Technical data
Model |
YCF8-1085 |
YCF8-1485 |
Rated current In(A) |
2-32A |
40-50A |
Fuse size |
10×85 |
14×85 |
Rated working voltage Ue(V) |
DC1500 |
Rated short-circuit breaking capacity (KA) |
20 |
Time constant(ms) |
1-3ms |
Operating level |
gPV |
Standard |
IEC60269-6, UL248-19 |
Test method
The agreed time and current of the fuse "gPV"
Rated current of the fuse "gPV" (A) |
Agreed time (h) |
Agreed current |
Inf |
If |
In ≤63 |
1 |
1.13In |
1.45In |
63<In ≤160 |
2 |
160<In ≤400 |
3 |
In>400 |
4 |
Joule integral table
Model |
Rated current |
Joule integral I²T(A²S) |
(A) |
Pre-arcing |
Total |
YCF8-1085 |
2 |
4 |
8 |
3 |
6 |
11 |
4 |
8 |
14 |
5 |
11 |
22 |
6 |
15 |
30 |
8 |
9 |
35 |
10 |
10 |
98 |
12 |
12 |
120 |
15 |
14 |
170 |
20 |
34 |
400 |
25 |
65 |
550 |
30 |
85 |
680 |
32 |
90 |
720 |
YCF8-1485 |
40 |
125 |
800 |
50 |
155 |
920 |
Curve
Overall and mounting dimensions(mm)
Base
Link
General
YCF8-□ □ PV series fuses have a rated operating voltage of DC1500V and a rated current of 80A. It is mainly used in the solar photovoltaic DC combiner box to break the line overload and short-circuit current generated by the current feedback of the photovoltaic components of the solar panel and the inverter, so as to protect the solar photovoltaic components. It is widely used in the circuit protection of electric drive system, power supply system and auxiliary system, and the fuse can also be selected in any other DC circuit as the circuit overload and short circuit protection of electrical components.
Standard: IEC60269, UL4248-19.
Features
The fuse base is made of a plastic pressed shell with contacts and fuse-carrying parts, which are riveted and connected, and can be used as the supporting part of the fuse link of corresponding size. This series of fuses has the characteristics of small size, convenient installation, safe use and beautiful appearance.
Selection
YCF8 |
- |
32 |
X |
PV |
DC1500 |
Model |
Shell frame |
Functions |
Product type |
Rated Voltage |
Fuse |
32: 1~32A |
/:standard X: With display H: High base |
PV:
Photovoltaic/ direct-current |
DC1000V |
63: 15~40A |
/:non |
DC1000V |
125: 40~80A |
DC1500V |
Fuse
Fuse holder |
Assembly fuse |
YCF8-32 |
YCF8-1038 |
YCF8-63 |
YCF8-1451 |
YCF8-125 |
YCF8-2258 |
Technical data
Model |
YCF8-32PV |
YCF8-63PV |
YCF8-125PV |
Specifications |
/:standard X: With display H: High base |
/:standard |
/:standard |
Fuse size(mm) |
10 ×38 |
14 ×51 |
22 ×58 |
Rated working voltage Ue(V) |
DC1000 |
DC1500 |
Rated insulation voltage Ui(V) |
DC1500 |
Use category |
gPV |
Standard |
IEC60269-6, UL4248-19 |
Number of poles |
1P |
Operating environment and installation |
|
Working temperature |
-40℃≤X≤+90℃ |
Altitude |
≤2000m |
Humidity |
When the maximum temperature is+40℃, the relative humidity of the air shall not exceed 50%, and higher humidity can be allowed at lower temperatures, For example+ 90% at 25℃ Special measures shall betaken for occasional condensation due to temperature changes; |
Installation environment |
In a place where there is no explosive medium and the medium is not enough to corrode metal and damage insulation gas and conductive dust. |
Pollution degree |
Level 3 |
Installation category |
III |
Installation method |
TH-35 Din-rail installation |
General
The variable cross-section melt made of pure silver sheet (or silver wire winding) is soldered with low-temperature tin and packaged in a fusion tube made of high- strength porcelain. The fusion tube is filled with chemically treated and specially processed Process-treated high-purity quartz sand is used as the arc-extinguishing medium, and the two ends of the melt are firmly electrically connected with the contacts by electric welding.
Selection
YCF8 |
- |
1038 |
25A |
DC1500 |
Model |
Size |
Rated current |
Rated voltage |
Fuse |
1038: 10×38 |
1,2,3,4,5,6,8,10,15,
16,20,25,30,32 |
DC1000V |
1451: 14×51 |
15,16,20,25,30,
32,40,50 |
DC1000V |
2258: 22×58 |
40,50,63,80 |
DC1500V |
Technical data
Model |
YCF8-1038 |
YCF8-1451 |
YCF8-2258 |
Rated current In(A) |
1,2,3,4,5,6,8,10,12,15,
20,25,30,32 |
15,20,25,30,32,40,50 |
40,50,63,80 |
Specifications |
/
X: With display
H: High base |
/ |
/ |
Fuse size(mm) |
10×38 |
14×51 |
22×58 |
Rated working voltage Ue(V) |
DC1000 |
DC1000,DC1500 |
Rated short-circuit breaking capacity (KA) |
20 |
Time constant(ms) |
1-3ms |
Operating level |
gPV |
Standards |
IEC60269-6, UL248-19 |
Test method
The agreed time and current of the fuse "gPV"
Rated current of
the fuse "gPV"
(A) |
Agreed time
(h) |
Agreed current |
Inf |
If |
In ≤63 |
1 |
1.13In |
1.45In |
63<In ≤160 |
2 |
160<In ≤400 |
3 |
In>400 |
4 |
Joule integral table
Model |
Rated current
(A) |
Joule integral I²T(A²S) |
Pre-arcing |
Total |
YCF8-1038 |
1 |
0.15 |
0.4 |
2 |
1.2 |
3.3 |
3 |
3.9 |
11 |
4 |
10 |
27 |
5 |
18 |
48 |
6 |
31 |
89 |
8 |
3.1 |
31 |
10 |
7.2 |
68 |
12 |
16 |
136 |
15 |
24 |
215 |
16 |
28 |
255 |
20 |
38 |
392 |
25 |
71 |
508 |
30 |
102 |
821 |
32 |
176 |
976 |
YCF8-1451 |
15 |
330 |
275 |
20 |
220 |
578 |
25 |
275 |
956 |
30 |
380 |
1160 |
32 |
405 |
1830 |
40 |
600 |
2430 |
50 |
850 |
3050 |
YCF8-2258 |
40 |
750 |
3450 |
50 |
1020 |
5050 |
63 |
|
|
80 |
|
|
Curve
Overall and mounting dimensions(mm)
Base
Link