General
In order to satisfy the demands of various pumping applications, YCB2000PV solar pump controller adopts Max Power Point Tracking and proven motor drive technology to maximize output from solar modules. It supports both single phase or three-phase AC input such as a generator or inverter from battery. The controller provides fault detection, motor soft start, and speed control. YCB2000PV controller is designed to proceed these features with the plug and play, ease of installation.
Selection
YCB2000PV |
— |
T |
5D5 |
G |
Model |
Output voltage |
Adaptive power |
Load type |
Photovoltaic Inverter |
S: Single phase AC220V
T: Three phase AC380V |
0D75:0.75KW
1D5:1.5KW
2D2:2.2KW
4D0:4.0KW
5D5:5.5KW
7D5:7.5KW
011:11KW
015:15KW
....
110:110KW |
G: Constant torque |
Flexibility
Compatible with IEC standard three- phase asynchronous induction motors Compatible weth popular PV arrays
Grid supply option
Remote monitoring
Standard Rs485 interface equipped for each solar pump controller
Optional GPRS/Wi-Fi/ Erhernet Rj45 modules for remote access
Spots value of solar pump parameters monitoring available from anywhere History of solar pump parameters and events lookup support
Android/iOS monitoring APP support
Cost effectiveness
Plug-and-play system design
Embedded motor protection and pump functions
Battery-free for most applications Effortless maintenance
Reliability
10-year market proven experience of leading motor and pump drive technology
Soft start feature to prevent water hammer and increase system life
Built-in overvoltage ,overload ,overheat and dry- run protection
Smartness
Self-adaptive maximum power point
tracking technology up to 99% efficiency Automatic regulation of pump flow
Self-adaptation to the motor used in the installation |
Protection
Surge protection
Overvoltage protection Undervoltage protection Locked pump protection Open circuit protection Short circuit protection Overheat protection
Dry run protection
General data
Ambient Temperature Tange: -20 ° C~60 ° C ,
〉45 ° C , Derating as required
Cooling Method :Fan Cooling Ambient Humidity:≤95% RH
|
Technical data
Model |
YCB2000PV-S0D7G |
YCB2000PV-S1D5G |
YCB2000PV-S2D2G |
YCB2000PV-T2D2G |
YCB2000PV-T4D0G |
Input data |
PV Source |
Max input voltage(Voc)[V] |
400 |
750 |
Min input voltage, at mpp[V] |
180 |
350 |
Recommended voltage,at mpp |
280VDC~360VDC |
500VDC~600VDC |
Recommended amps input,at mpp[A] |
4.7 |
7.3 |
10.4 |
6.2 |
11.3 |
Recommended max power at mpp[kW] |
1.5 |
3 |
4.4 |
11 |
15 |
Output data |
Input voltage |
220/230/240VAV(±15%),Single Phase |
380VAV(±15%),Three Phase |
Max amps(RMS)[A] |
8.2 |
14 |
23 |
5.8 |
10 |
Power and va capability [kVA] |
2 |
3.1 |
5.1 |
5 |
6.6 |
|
|
|
|
|
|
Rated output power[kW] |
0.75 |
1.5 |
2.2 |
2.2 |
4 |
Rated output voltage |
220/230/240VAC,Single Phase |
380VAC,Three Phase |
Max amps(RMS)[A] |
4.5 |
7 |
10 |
5 |
9 |
Output frequency |
0-50Hz/60Hz |
Pump system configuration parameters |
Recommended solar panel power(KW) |
1.0-1.2 |
2.0-2.4 |
3.0-3.5 |
3.0-3.5 |
5.2-6.4 |
Solar panel connection |
250W×5P×30V |
250W×10P×30V |
250W×14P×30V |
250W×20P×30V |
250W×22P×30V |
Applicable pump (kW) |
0.37-0.55 |
0.75-1.1 |
1.5 |
1.5 |
2.2-3 |
Pump motor voltage(V) |
3 phase 220 |
3 phase 220 |
3 phase 220 |
3 phase 380 |
3 phase 380 |
Technical data
Model |
YCB2000PV-T5D5G |
YCB2000PV-T7D5G |
YCB2000PV-T011G |
YCB2000PV-T015G |
YCB2000PV-T018G |
Input data |
PV source |
Max input voltage(Voc)[V] |
750 |
Min input voltage, at mpp[V] |
350 |
Recommended voltage,at mpp |
500VDC~600VDC |
Recommended amps input,at mpp[A] |
16.2 |
21.2 |
31.2 |
39.6 |
46.8 |
Recommended max power at mpp[kW] |
22 |
30 |
22 |
30 |
37 |
Alternate AC generator |
Input voltage |
380VAV(±15%) ,Three Phase |
Max amps(RMS)[A] |
15 |
20 |
26 |
35 |
46 |
Power and va capability [kVA] |
9 |
13 |
17 |
23 |
25 |
Output data |
Rated output power[kW] |
5.5 |
7.5 |
11 |
15 |
18.5 |
Rated output voltage |
380VAC,Three Phase |
Max amps(RMS)[A] |
13 |
17 |
25 |
32 |
37 |
Output frequency |
0-50Hz/60Hz |
Pump system configuration parameters |
Recommended solar panel power(KW) |
7.2-8.8 |
9.8-12 |
14.3-17.6 |
19.5-24 |
24-29.6 |
Solar panel connection |
250W×40P×30V
20 series 2 parallel |
250W×48P×30V 24 series 2 parallel |
250W×60P×30V 20 series 3 parallel |
250W×84P×30V 21 series 4 parallel |
250W×100P×30V 20 series 5 parallel |
Applicable pump (kW) |
3.7-4 |
4.5-5.5 |
7.5-9.2 |
11-13 |
15 |
Pump motor voltage(V) |
3 phase 380 |
3 phase 380 |
3 phase 380 |
3 phase 380 |
3 phase 380 |
Technical data
Model |
YCB2000PV-T022G |
YCB2000PV-T030G |
YCB2000PV-T037G |
YCB2000PV-T045G |
Input data |
PV source |
Max input voltage(Voc)[V] |
750 |
Min input voltage, at mpp[V] |
350 |
Recommended voltage,at mpp |
500VDC~600VDC |
Recommended amps input,at mpp[A] |
56 |
74 |
94 |
113 |
Recommended max power at mpp[kW] |
44 |
60 |
74 |
90 |
Alternate AC generator |
Input voltage |
380VAV(±15%) ,Three Phase |
Max amps(RMS)[A] |
62 |
76 |
76 |
90 |
Power and va capability [kVA] |
30 |
41 |
50 |
59.2 |
Output data |
Rated output power[kW] |
22 |
30 |
37 |
45 |
Rated output voltage |
380VAC,Three Phase |
Max amps(RMS)[A] |
45 |
60 |
75 |
90 |
Output frequency |
0-50Hz/60Hz |
Pump system configuration parameters |
Recommended solar panel power(KW) |
28.6-35.2 |
39-48 |
48.1-59.2 |
58.5-72 |
Solar panel connection |
250W×120P×30V
20 series 6 parallel |
250W×200P×30V
20 series 10 parallel |
250W×240P×30V
22 series 12 parallel |
250W×84P×30V
21 series 4 parallel |
Applicable pump (kW) |
18.5 |
22-26 |
30 |
37-40 |
Pump motor voltage(V) |
3 phase 380 |
3 phase 380 |
3 phase 380 |
3 phase 380 |
Technical data
Model |
YCB2000PV-T055G |
YCB2000PV-T075G |
YCB2000PV-T090G |
YCB2000PV-T110G |
Input data |
PV source |
Max input voltage(Voc)[V] |
750 |
Min input voltage, at mpp[V] |
350 |
Recommended voltage,at mpp |
500VDC~600VDC |
Recommended amps input,at mpp[A] |
105 |
140 |
160 |
210 |
Recommended max power at mpp[kW] |
55 |
75 |
90 |
110 |
Alternate AC generator |
Input voltage |
380VAV(±15%) ,Three Phase |
Max amps(RMS)[A] |
113 |
157 |
180 |
214 |
Power and va capability [kVA] |
85 |
114 |
134 |
160 |
Output data |
Rated output power[kW] |
55 |
75 |
93 |
110 |
Rated output voltage |
380VAC,Three Phase |
Max amps(RMS)[A] |
112 |
150 |
176 |
210 |
Output frequency |
0-50Hz/60Hz |
Pump system configuration parameters |
Recommended solar panel power(KW) |
53-57 |
73-80 |
87-95 |
98-115 |
Solar panel connection |
400W*147P*30V 21series 7 parallel |
400W*200P*30V
20 series 10 parallel |
400W*240P*30V
20 series 12 parallel |
400W*280P*30V
20 series 4 parallel |
Applicable pump (kW) |
55 |
75 |
90 |
110 |
Pump motor voltage(V) |
3PH 380V |
External dimension
Size
Model |
W(mm) |
H(mm) |
D(mm) |
A(mm) |
B(mm) |
Mounting Aperture |
YCB2000PV-S0D7G |
125 |
185 |
163 |
115 |
175 |
4 |
YCB2000PV-S1D5G |
YCB2000PV-S2D2G |
YCB2000PV-T0D7G |
YCB2000PV-T1D5G |
YCB2000PV-T2D2G |
YCB2000PV-T3D0G |
150 |
246 |
179 |
136 |
230 |
4 |
YCB2000PV-T4D0G |
YCB2000PV-T5D5G |
YCB2000PV-T7D5G |
YCB2000PV-T011G |
218 |
320 |
218 |
201 |
306 |
5 |
YCB2000PV-T015G |
YCB2000PV-T018G |
YCB2000PV-T022G |
235 |
420 |
210 |
150 |
404 |
5 |
YCB2000PV-T030G |
270 |
460 |
220 |
195 |
433 |
6 |
YCB2000PV-T037G |
YCB2000PV-T045G |
320 |
565 |
275 |
240 |
537 |
6 |
YCB2000PV-T055G |
YCB2000PV-T075G |
380 |
670 |
272 |
274 |
640 |
8 |
YCB2000PV-T090G |
YCB2000PV-T110G |
Overall and mounting dimensions(mm)
Scenic spot of daocheng yading, shangri-la:
System installed in Scenic Spot of Daocheng Yading, Shangri-la to cloth barren mountains with greenery scene. 3pcs 37kW solar pumps, 3PCS YCB2000PV-T037G Solar Pump Controllers.
System capacity: 160KW
Panels: 245W
Altitude: 3400M
Pumping3height: 250M
Flow: 69M / H